Threat intel4 min read
SonicWall ends Gen 6 firewall patches, even for critical flaws
SonicWall says Gen 6 and Gen 6.5 firewalls on SonicOS 6.x have reached end of support and will get no more security fixes. It wants them replaced with Gen 8 now.
4Tify Team

SonicWall has told every customer still running a Generation 6 firewall to take it out of service. In a product advisory dated 18 November 2026, the company says Gen 6 has reached end of support and will receive no more firmware updates or security patches, even when a newly found flaw is rated Critical.
What happened
The advisory covers all Gen 6 and Gen 6.5 appliances running SonicOS 6.x, including the Gen 6 NSv virtual firewalls. Support contracts for these models can no longer be bought or renewed. SonicWall says it expects internet-facing Gen 6 units to be actively targeted, and that attackers now use automation and AI to find unsupported edge devices faster than before.
In practice this means that from now on, any vulnerability disclosed in SonicOS 6.x stays open on these devices for good. A fix shipped for a newer generation can also point attackers to the same weakness in older code.
Who is affected
Support ended on different dates depending on the model. Per SonicWall's lifecycle table:
- 1 October 2026: TZ350, TZ350W, TZ500, TZ500W, SOHO 250, SOHO 250W, NSA 4600, NSA 5600, NSA 6600, NSa 4650, NSa 5650, NSa 6650
- 1 August 2026: TZ400, TZ400W, TZ600, TZ600P, NSA 3600, NSa 3650
- 1 May 2026: NSa 2650
- 16 April 2026: SOHO, SOHO W, TZ300P, NSa 9250, NSa 9450, NSa 9650, NSv 10 to NSv 1600
- 20 February 2026: SuperMassive 9200, 9400, 9600, 9800, NSsp 12400, NSsp 12800
- Earlier: TZ300 and TZ300W (23 January 2025), NSA 2600 (8 March 2024)
If one of these boxes sits at your network edge, handles SSL VPN or exposes its management interface to the internet, it is the kind of device the warning is about.
Why this matters
Edge firewalls are an attractive target because they see all traffic in and out and often hold VPN credentials. SonicOS has a history here. CVE-2024-40766, an improper access control flaw in SonicOS management access with a CVSS score of 9.3, affected Gen 5, Gen 6 and early Gen 7 firewalls. CISA added it to its Known Exploited Vulnerabilities catalog in September 2024 and lists it as used in ransomware campaigns. At the time, Gen 6 owners could patch. The next bug of that kind will have no Gen 6 fix.
What to do now
SonicWall's recommended path, in order:
- Find every Gen 6 unit. Include spares, lab boxes and firewalls at branch offices, which are easy to forget.
- Rank them by exposure. Units reachable from the internet or offering remote access (SSL VPN, WAN management) go first.
- Replace them with a Gen 8 firewall running SonicOS 8. Supported settings from SonicOS 6.5 can be carried over with the in-product import or the NSM Migration App, so the rule base does not need to be rebuilt by hand.
- Work with an authorised SonicWall partner to schedule the swap.
Until the hardware is replaced, SonicWall lists these steps to cut exposure. They reduce risk; they do not make the device safe:
- Turn off WAN management (HTTPS, SSH and SNMP on WAN interfaces).
- Disable SSL VPN, or allow it only from known IP addresses.
- Require multi-factor authentication on every remote-access and admin account, and reset local passwords.
- Disable services and interfaces you don't use.
- Watch the logs for unusual logins, configuration changes and traffic.
The full model list and steps are in SonicWall's advisory.
How we can help
The hard part is often the first step: knowing which old appliances are still reachable from the internet, including the one at a branch office nobody has logged into for a year. Our Attack Surface Management service maps your internet-facing assets continuously and flags devices that expose management or VPN portals, so end-of-life firewalls show up before an attacker finds them.